Sign In | Join Free | My
Hangzhou AGS MedTech Co.,Ltd.
Hangzhou AGS MedTech Co.,Ltd. Best Products! Best Service!
Home > Resolution Hemoclip >

Disposable Removable Resolution Hemoclip Ethylene Oxide Sterilization ISO 13485

Hangzhou AGS MedTech Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Hangzhou AGS MedTech Co.,Ltd.
City: Qianjiang
Province/State: Hubei
Country/Region: China
Tel: 86-571-87671223

Disposable Removable Resolution Hemoclip Ethylene Oxide Sterilization ISO 13485

Brand Name : AGS
Certification : CE
Place of Origin : China
Price : Negotiable
Payment Terms : T/T
Supply Ability : 100000 Unit/Units per Month
Delivery Time : 10 DAYS after payment
Packaging Details : Carton size: 54 x 38 x 33.5 cm GW: 8.0 KG, NW: 6.0 KG
Group : Adult and Pediatrics
Ethylene Oxide Sterilization : Ethylene Oxide Sterilization
HS Code : 9018909019
Endospcope : Gastroscope
Model Number : AG-
Contact Now

Disposable Removable Clip with ISO 13485 and CE as Hemoclip

Applicator Apply with Snare

Removable Clip System Introduction

Brand Name:AGS
Model Number:AG-5104-2300-090
Place of Origin:China
Minimum Order Quantity:200PCS
Payment Terms:L/C, T/T
Supply Ability:8000pcs/week
Delivery Time:10~15 workdays
Packaging Details:5pcs/box,10boxes/ carton
Material:Stainless steel, ABS, PE
Ethylene Oxide Sterilization:Ethylene Oxide Sterilization
Transport Package:Standard Cartons

Step 1 Insert the Polypectomy Snare and make it near the Clip

1.1, Revolve the endoscope or proper air admission , in order to put the clip in the middle of the field of vision;

1.2, Insert the Polypectomy Snare until it appears in the field of vision;

1.3, Suggest to use rotatable 10mm(width of Ele Ctrode) size snare. The wire OD should be 0.36~0.38m.

Step 2 Adjust the Snare angle and position

2.1, Revolve the Snare or the Endoscope, make the angle between Clip and Snare to be 60°~90°;

2.2 Keep Snare and Clip groove Not vertical .If they are already vertical, use the Endoscope left-right button to adjust the angle.

Step 3 Circle the clip

3.1, Use the Snare to circle the clip ,and then tighten the Snare.

Suggest to put the snare at clip 1/3 length position (A position).But must make sure the snare under clip step;

3.2, Always keep the clip under Snare Circle.

Step 4 Let the Snare move Clip Groove

4.1, Revolve the Endoscope ,drive the Snare completely move into the Clip Groove;

4.2, Revolve the Endoscope to make clip left-right move ,in order to check if the Snare already at the right position.

Step 5 Tighten the Snare

5.1 Pull the Snare handle to the end (Or till you can not pull);

5.2 Properly take back the Endoscope or put forward the Snare ,which offers a better visual field for observing the contact position between Clip and Tissue.

Step 6 Check if the Clip already drop from Tissue

6.1, Use the Endoscope to move up the Snare;

6.2, Feel the Endoscope move force to check if the already drop from Tissue;

6.3, Observe the contact position of the Clip and Tissue to check if the Clip already drop from Tissue.

Step 7 Clip take out

7.1, Take out the Endoscope which also takes the clip out of human body;

7.2 Or you can release the Snare and continue surgery ,after finish all other procedures ,pls don’t forget to take out the Clip.

Product Tags:

resolution clip device


haemostatic clips

China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Disposable Removable Resolution Hemoclip Ethylene Oxide Sterilization ISO 13485 Images

Inquiry Cart 0
Send your message to this supplier
Enter your email please.
To: Hangzhou AGS MedTech Co.,Ltd.
Characters Remaining: (0/3000)