Sign In | Join Free | My
Hangzhou AGS MedTech Co.,Ltd.
Hangzhou AGS MedTech Co.,Ltd. Best Products! Best Service!
Home > Resolution Hemoclip >

AGS Medtech Endoscopic Hemoclip Snare Angle Adjustable Ergonomic Design

Hangzhou AGS MedTech Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Hangzhou AGS MedTech Co.,Ltd.
City: Qianjiang
Province/State: Hubei
Country/Region: China
Tel: 86-571-87671223

AGS Medtech Endoscopic Hemoclip Snare Angle Adjustable Ergonomic Design

Brand Name : AGS
Certification : CE
Place of Origin : China
Price : Negotiable
Payment Terms : T/T
Supply Ability : 100000 Unit/Units per Month
Delivery Time : 10 DAYS after payment
Packaging Details : CARTON
Group : Adult and Pediatrics
Origin : Hangzhou,
Ethylene Oxide Sterilization : Ethylene Oxide Sterilization
HS Code : 9018909019
Advantage : Integrated design without installation
feature : convenient
Model Number : AG-
Contact Now

Easy to Operate!! Hangzhou AGS Medtech Endoscopic Disposable


Hemoclip placement for bleeding of GI tract seems to be very convenient now and may become common in the world in the future.

Removable Clip System Introduction

Step 1 Insert the Polypectomy Snare and make it near the Clip

1.1, Revolve the endoscope or proper air admission , in order to put the clip in the middle of the field of vision;

1.2, Insert the Polypectomy Snare until it appears in the field of vision;

1.3, Suggest to use rotatable 10mm(width of Ele Ctrode) size snare. The wire OD should be 0.36~0.38mm.

Step 2 Adjust the Snare angle and position

2.1, Revolve the Snare or the Endoscope, make the angle between Clip and Snare to be 60°~90°;

2.2, Keep Snare and Clip groove Not vertical .If they are already vertical, use the Endoscope left-right button to adjust the angle.

Step 3 Circle the clip

3.1, Use the Snare to circle the clip ,and then tighten the Snare.

Suggest to put the snare at clip 1/3 length position (A position).But must make sure the snare under clip step;

3.2, Always keep the clip under Snare Circle.

Step 4 Let the Snare move Clip Groove

4.1, Revolve the Endoscope ,drive the Snare completely move into the Clip Groove;

4.2, Revolve the Endoscope to make clip left-right move ,in order to check if the Snare already at the right position.

Step 5 Tighten the Snare

5.1 Pull the Snare handle to the end (Or till you can not pull);

5.2, Properly take back the Endoscope or put forward the Snare ,which offers a better visual field for observing the contact position between Clip and Tissue.

Step 6 Check if the Clip already drop from Tissue

6.1, Use the Endoscope to move up the Snare;

6.2, Feel the Endoscope move force to check if the already drop from Tissue;

6.3, Observe the contact position of the Clip and Tissue to check if the Clip already drop from Tissue.

Step 7 Clip take out

7.1, Take out the Endoscope which also takes the clip out of human body;

7.2, Or you can release the Snare and continue surgery ,after finish all other procedures ,pls don’t forget to take out the Clip.

Product Tags:

resolution clip device


haemostatic clips

China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

AGS Medtech Endoscopic Hemoclip Snare Angle Adjustable Ergonomic Design Images

Inquiry Cart 0
Send your message to this supplier
Enter your email please.
To: Hangzhou AGS MedTech Co.,Ltd.
Characters Remaining: (0/3000)